Public water system · CO0153701
ActiveSan Luis Valley Research Center
At a glance
San Luis Valley Research Center (PWSID CO0153701) is an active non-transient non-community water system in Rio Grande County, Colorado. It reports serving 45 people through 5 service connections. Its primary water source is groundwater, and EPA lists it as privately owned. EPA's records list 3 violations for this system; none is health-based, and the most recent began in July 2019.
Dataset updated . Source: EPA SDWIS/ECHO public records.
Population served
45
Service connections
5
Primary source
GW
Groundwater
System type
NTNCWS
Non-transient non-community water system
System record
How does San Luis Valley Research Center compare with other water systems in Rio Grande County?
By EPA's size categories, San Luis Valley Research Center is a very small system (500 people or fewer). Rio Grande County has 48 active public water systems. Its population served is well below the county average of 289 people per system, and accounts for 0.3% of the 13,885 people reported by systems filed under the county. Across Colorado, the 2,207 active systems average 3,400 people each. Nationally, the average active non-transient non-community water system reports serving 430 people, so San Luis Valley Research Center is well below that figure.
What does “non-transient non-community water system” mean?
A non-transient non-community water system regularly serves at least 25 of the same people for more than six months a year, but not where they live. Schools, factories, office buildings and hospitals with their own supply are typical examples. Colorado has 183 active non-transient non-community water systems, 8.3% of the state's 2,207 active systems. Groundwater means the system draws its water from wells or springs fed by underground aquifers. 1,437 Colorado systems (65%) list groundwater as their primary source.
Who owns and regulates San Luis Valley Research Center?
EPA lists San Luis Valley Research Center as privately owned. The CO state drinking water program is its primacy agency, the regulator with primary enforcement responsibility for the system under the Safe Drinking Water Act. 40 of the 48 active systems in Rio Grande County (83%) are also privately owned.
Does San Luis Valley Research Center have drinking water violations?
EPA's records list 3 violations for this system; none is health-based, and the most recent began in July 2019. The violations listed here began between July 2018 and July 2019. By type: 2 monitoring and 1 public notice, recordkeeping or other. The contaminant or rule involved most often is Revised Total Coliform Rule (2 of them). EPA lists 3 as resolved. Resolved means at least one resolving action is on record: the system returned to compliance, the rule no longer applies, or no further action was needed.
| Began | Violation | Contaminant or rule | Health-based | Status |
|---|---|---|---|---|
| 2019-07-01 | MonitoringMonitoring, Routine (RTCR) · code 3A | Revised Total Coliform Rulecode 8000 | No | Resolved |
| 2019-01-01 | Public notice, recordkeeping or otherPublic Notification Violation without NPDWR Violation · code 76 | Public Noticecode 7500 | No | Resolved |
| 2018-07-01 | MonitoringMonitoring, Routine (RTCR) · code 3A | Revised Total Coliform Rulecode 8000 | No | Resolved |
All 3 violations in EPA's records, newest first.Labels and codes come from EPA's SDWIS reference tables. A monitoring or reporting violation means a required test or report was missed or late; it does not by itself mean a contaminant was found. "Health-based" marks violations of a legal limit or required treatment.
San Luis Valley Research Center: frequently asked questions
Who runs San Luis Valley Research Center?
San Luis Valley Research Center (PWSID CO0153701) is a non-transient non-community water system privately owned. It is regulated by the CO state drinking water program.
How many people does San Luis Valley Research Center serve?
San Luis Valley Research Center reports serving 45 people through 5 service connections in Rio Grande County, Colorado.
Where does San Luis Valley Research Center get its water?
EPA SDWIS lists this system's primary water source as groundwater. Groundwater means the system draws its water from wells or springs fed by underground aquifers.
Does San Luis Valley Research Center have any drinking water violations?
EPA's records list 3 violations for this system; none is health-based, and the most recent began in July 2019. A monitoring or reporting violation means a required test or report was missed or late; it does not by itself mean a contaminant was found.
Is San Luis Valley Research Center's water safe to drink?
AquaCensus shows EPA compliance records, not current water test results, so it cannot say whether the water is safe at a given moment. EPA's records list 3 violations for this system; none is health-based, and the most recent began in July 2019. For current results, consult EPA ECHO, or the CO state drinking water program.
Where can I find San Luis Valley Research Center's water quality report?
The annual Consumer Confidence Report requirement applies to community water systems. San Luis Valley Research Center is a non-transient non-community water system, so it is not required to publish one; like every public water system, it must notify the people it serves about violations under EPA's public notification rules.
Other water systems in Rio Grande County
| Water system | County | Population served | Type | Source |
|---|---|---|---|---|
| Monte Vista City of | Rio Grande | 4,600 | Community | Groundwater |
| Fun Valley Resort | Rio Grande | 1,723 | Transient non-community | Groundwater |
| Del Norte Town of | Rio Grande | 1,429 | Community | Groundwater |
| South Fork Rickel Park | Rio Grande | 804 | Transient non-community | Groundwater |
| South Fork West Municipal Town of | Rio Grande | 566 | Community | Groundwater |
| Sargent Elem and New High School Re33 | Rio Grande | 426 | Non-transient non-community | Groundwater |
Related pages
Working with water-system records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.
About this data
Source: U.S. EPA Safe Drinking Water Information System (SDWIS) and SDWA violation records, via EPA ECHO, as published October 1, 2026 — AquaCensus refreshes it quarterly. See the methodology for how records are matched, cleaned and scored.
Cite as: AquaCensus, “San Luis Valley Research Center, PWSID CO0153701, Colorado”, https://aquacensus.com/water-systems/colorado/san-luis-valley-research-center-co0153701 (data as of October 1, 2026).