Skip to content
AquaCensus

Public water system · TX0390019

Active

Dean Dale Sud

At a glance

Dean Dale Sud (PWSID TX0390019) is an active community water system in Clay County, Texas. It reports serving 2,492 people through 1,450 service connections. Its primary water source is purchased surface water, and EPA lists it as owned by a local government. Of the 12 most recent violations in EPA's records, 4 are health-based, and the most recent began in July 2025.

Dataset updated . Source: EPA SDWIS/ECHO public records.

Population served

2,492

Service connections

1,450

Primary source

SWP

Purchased surface water

System type

CWS

Community water system

System record

PWSIDTX0390019
System typeCommunity water system
Activity statusActive
Population served2,492
Service connections1,450
Primary water sourcePurchased surface water
Owner typeLocal government
Primacy agencyTX state drinking water program
City served—
StateTexas
ZIP—
CountyClay County

How does Dean Dale Sud compare with other water systems in Clay County?

By EPA's size categories, Dean Dale Sud is a small system (501 to 3,300 people). Clay County has 10 active public water systems, and Dean Dale Sud is the 2nd-largest of them by population served. Its population served is about 177% above the county average of 898 people per system, and accounts for 28% of the 8,983 people reported by systems filed under the county. Across Texas, the 7,078 active systems average 4,789 people each. Nationally, the average active community water system reports serving 6,703 people, so Dean Dale Sud is about 63% below that figure.

What does “community water system” mean?

A community water system serves at least 15 connections used by year-round residents, or regularly serves at least 25 year-round residents. Homes, apartments and mobile-home parks are served by these. Texas has 4,594 active community water systems, 65% of the state's 7,078 active systems. Purchased surface water means the system buys surface water from another public water system rather than drawing its own. 1,192 Texas systems (17%) list purchased surface water as their primary source.

Who owns and regulates Dean Dale Sud?

EPA lists Dean Dale Sud as owned by a local government. The TX state drinking water program is its primacy agency, the regulator with primary enforcement responsibility for the system under the Safe Drinking Water Act. 9 of the 10 active systems in Clay County (90%) are also owned by a local government.

Does Dean Dale Sud have drinking water violations?

Of the 12 most recent violations in EPA's records, 4 are health-based, and the most recent began in July 2025. The violations listed here began between January 1979 and July 2025. By type: 5 monitoring and reporting, 4 contaminant level above the legal limit, 2 public notice, recordkeeping or other and 1 reporting. The contaminant or rule involved most often is Nitrate (4 of them). EPA lists 7 as resolved, 4 as archived and 1 as unaddressed. Resolved means at least one resolving action is on record: the system returned to compliance, the rule no longer applies, or no further action was needed. Archived means the violation was not marked resolved but is more than five years past the end of the noncompliance period, so it no longer counts toward current compliance status. Unaddressed means the violation is not resolved or archived and is not yet covered by formal enforcement.

BeganViolationContaminant or ruleHealth-basedStatus
2025-07-02ReportingNotification, Known or Potential LSL · code 4HLead and Copper Rule Revisionscode 5200NoUnaddressed
2025-07-01Public notice, recordkeeping or otherConsumer Confidence Report Inadequate Reporting · code 72Consumer Confidence Rulecode 7000NoResolved
2015-12-30Monitoring and reportingLead Consumer Notice · code 66Lead and Copper Rulecode 5000NoResolved
2015-10-01Monitoring and reportingFollow-up Or Routine LCR Tap M/R · code 52Lead and Copper Rulecode 5000NoResolved
2008-10-01Monitoring and reportingMonitoring and Reporting (DBP) · code 27Chlorinecode 0999NoResolved
2004-09-01Monitoring and reportingMonitoring, Routine Major (TCR) · code 23Total coliform bacteria (TCR)code 3100NoResolved
2003-05-01Public notice, recordkeeping or otherPublic Notification Violation for NPDWR Violation · code 75Public Noticecode 7500NoResolved
2003-01-01Monitoring and reportingMonitoring, Routine Minor (TCR) · code 24Total coliform bacteria (TCR)code 3100NoResolved
1994-11-15Contaminant level above the legal limitMaximum Contaminant Level Violation, Average · code 02Nitratecode 1040YesArchived
1989-12-13Contaminant level above the legal limitMaximum Contaminant Level Violation, Average · code 02Nitratecode 1040YesArchived
1986-10-22Contaminant level above the legal limitMaximum Contaminant Level Violation, Average · code 02Nitratecode 1040YesArchived
1979-01-26Contaminant level above the legal limitMaximum Contaminant Level Violation, Average · code 02Nitratecode 1040YesArchived

The 12 most recent violations in EPA's records, newest first.Labels and codes come from EPA's SDWIS reference tables. A monitoring or reporting violation means a required test or report was missed or late; it does not by itself mean a contaminant was found. "Health-based" marks violations of a legal limit or required treatment.

Dean Dale Sud: frequently asked questions

Who runs Dean Dale Sud?

Dean Dale Sud (PWSID TX0390019) is a community water system owned by a local government. It is regulated by the TX state drinking water program.

How many people does Dean Dale Sud serve?

Dean Dale Sud reports serving 2,492 people through 1,450 service connections in Clay County, Texas.

Where does Dean Dale Sud get its water?

EPA SDWIS lists this system's primary water source as purchased surface water. Purchased surface water means the system buys surface water from another public water system rather than drawing its own.

Does Dean Dale Sud have any drinking water violations?

Of the 12 most recent violations in EPA's records, 4 are health-based, and the most recent began in July 2025. A monitoring or reporting violation means a required test or report was missed or late; it does not by itself mean a contaminant was found.

Is Dean Dale Sud's water safe to drink?

AquaCensus shows EPA compliance records, not current water test results, so it cannot say whether the water is safe at a given moment. Of the 12 most recent violations in EPA's records, 4 are health-based, and the most recent began in July 2025. For current results, consult the system's annual water quality report, EPA ECHO, or the TX state drinking water program.

Where can I find Dean Dale Sud's water quality report?

As a community water system, Dean Dale Sud must deliver an annual water quality report, called a Consumer Confidence Report, to its customers by July 1 each year, covering the previous calendar year. The system can provide a copy on request.

Other water systems in Clay County

Water systemCountyPopulation servedTypeSource
City of HenriettaClay3,111CommunitySurface water
Rra Arrowhead Lake LotsClay1,770CommunityPurchased surface water
City of PetroliaClay514CommunityGroundwater
City of ByersClay446CommunityPurchased surface water
City of BellevueClay289CommunityGroundwater
Midway IsdClay164Non-transient non-communityGroundwater

Related pages

Working with water-system records? Pro adds alerts, change history and CSV export ($49/mo); Enterprise adds full national files, the API and an MCP server for AI tools.

About this data

Source: U.S. EPA Safe Drinking Water Information System (SDWIS) and SDWA violation records, via EPA ECHO, as published October 1, 2026 — AquaCensus refreshes it quarterly. See the methodology for how records are matched, cleaned and scored.

Cite as: AquaCensus, “Dean Dale Sud, PWSID TX0390019, Texas”, https://aquacensus.com/water-systems/texas/dean-dale-sud-tx0390019 (data as of October 1, 2026).